150 research outputs found

    State of the art: iterative CT reconstruction techniques

    Get PDF
    Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging

    Underground coal mine : Herrin (no. 6) coal member, stratigraphy, deformational structures, and roof stability

    Get PDF
    One-day Field Trip D, May 20, 1979. Prepared for Ninth International Congress of Carboniferous Stratigraphy and Geology (IX-ICC)Ope

    The Feasibility, Tolerability, Safety, and Accuracy of Low-radiation Dynamic Computed Tomography Myocardial Perfusion Imaging With Regadenoson Compared With Single-photon Emission Computed Tomography

    Get PDF
    Objectives: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. Materials and Methods: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. Results: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. Conclusions: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion

    Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence

    Get PDF
    Background: Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. While TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. Objectives: To investigate sensitivity, specificity and predictive value of cardiac CT angigography (cCTA), cardiac MRI (CMR), and TTE for recurrence in patients with suspected cardioembolic stroke. Methods: We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMR (n=75) or cCTA (n=76) between January 2013 and May 2017. We evaluated for presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end-point was stroke recurrence. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for recurrent stroke were calculated; the diagnostic accuracy of CMR, cCTA, and TTE was compared between and within groups using area under the curves (AUCs). Results: Twelve and 14 recurrent strokes occurred in the cCTA and CMR groups, respectively. Sensitivity, specificity, PPV and NPV were: 33.3%, 93.7%, 50.0%, and 88.2% for cCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMR; 14.3%, 83.6%, 16.7%, 80.9% for TTE in the CMR group, and 8.3%, 93.7%, 20.0% and 84.5% for TTE in the cCTA group. Accuracy was not different (p>0.05) between cCTA (0.63, 95% CI [0.49, 0.77]), CMR (0.53, [0.42, 0.63]), TTE in CMR group (0.51, [0.40, 0.61], and TTE in cCTA group (0.51, [0.42, 0.59]). In cCTA group, atrial and ventricular thrombus were detected by cCTA in 3 patients and TTE in 1 patient; in CMR group, thrombus was detected by CMR in 1 patient and TTE in 2 patients. Conclusion: cCTA, CMR, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. cCTA and CMR may be valid alternatives to TTE. cCTA may be preferred given potentially better detection of atrial and ventricular thrombus. Clinical impact: cCTA and CMR have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings

    Leadership Reconsidered: Engaging Higher Education in Social Change

    Get PDF
    Colleges and universities can provide effective environments for the development of future leaders. This book addresses the application of transformative leadership to higher education, identifies resources to use in the process, and..

    Accuracy of an Artificial Intelligence Deep Learning Algorithm Implementing a Recurrent Neural Network With Long Short-term Memory for the Automated Detection of Calcified Plaques From Coronary Computed Tomography Angiography

    Get PDF
    Purpose: The purpose of this study was to evaluate the accuracy of a novel fully automated deep learning (DL) algorithm implementing a recurrent neural network (RNN) with long short-term memory (LSTM) for the detection of coronary artery calcium (CAC) from coronary computed tomography angiography (CCTA) data. Materials and Methods: Under an IRB waiver and in HIPAA compliance, a total of 194 patients who had undergone CCTA were retrospectively included. Two observers independently evaluated the image quality and recorded the presence of CAC in the right (RCA), the combination of left main and left anterior descending (LM-LAD), and left circumflex (LCx) coronary arteries. Noncontrast CACS scans were allowed to be used in cases of uncertainty. Heart and coronary artery centerline detection and labeling were automatically performed. Presence of CAC was assessed by a RNN-LSTM. The algorithm's overall and per-vessel sensitivity, specificity, and diagnostic accuracy were calculated. Results: CAC was absent in 84 and present in 110 patients. As regards CCTA, the median subjective image quality, signal-to-noise ratio, and contrast-to-noise ratio were 3.0, 13.0, and 11.4. A total of 565 vessels were evaluated. On a per-vessel basis, the algorithm achieved a sensitivity, specificity, and diagnostic accuracy of 93.1% (confidence interval [CI], 84.3%-96.7%), 82.76% (CI, 74.6%-89.4%), and 86.7% (CI, 76.8%-87.9%), respectively, for the RCA, 93.1% (CI, 86.4%-97.7%), 95.5% (CI, 88.77%-98.75%), and 94.2% (CI. 90.2%-94.6%), respectively, for the LM-LAD, and 89.9% (CI, 80.2%-95.8%), 90.0% (CI, 83.2%-94.7%), and 89.9% (CI, 85.0%-94.1%), respectively, for the LCx. The overall sensitivity, specificity, and diagnostic accuracy were 92.1% (CI, 92.1%-95.2%), 88.9% (CI. 84.9%-92.1%), and 90.3% (CI, 88.0%-90.0%), respectively. When accounting for image quality, the algorithm achieved a sensitivity, specificity, and diagnostic accuracy of 76.2%, 87.5%, and 82.2%, respectively, for poor-quality data sets and 93.3%, 89.2% and 90.9%, respectively, when data sets rated adequate or higher were combined. Conclusion: The proposed RNN-LSTM demonstrated high diagnostic accuracy for the detection of CAC from CCTA
    corecore